How Much Ventilation Does a Buddy Heater Need Indoors?
How much ventilation does a Buddy Heater actually need? The answer is more specific than simply saying to “crack a window.”
According to the current Mr. Heater instructions, the Portable Buddy MH9BX requires at least 9 square inches of ventilation at the high opening and another 9 square inches at the low opening. The larger Big Buddy MH18B requires at least 18 square inches at the high opening and another 18 square inches at the low opening.
In other words, those numbers are per opening, not the combined total. For the Big Buddy, that works out to at least 36 square inches of total open area, divided between a high and low opening.
For example, the double-hung sash windows in my primary living space are 30 inches wide. That works out to be 18 square inches for my Big Buddy and an opening of about 5/8-inch across a 30-inch-wide sash. So I could open the lower sash of one window about 5/8 inch and open the upper sash of another window about the same amount.
That’s worth knowing if you’re using one during a winter power outage, in a cabin, hunting shelter, or other approved enclosure.
As an Amazon Associate I earn from qualifying purchases. There is no extra cost to you.
The two most common Mr. Heater Buddy models are the 9,000 BTU Portable Buddy MH9BX and the 18,000 BTU Big Buddy MH18B. I own both of them. They’re useful emergency heaters, but they’re still unvented propane appliances. “Indoor safe” does not mean “use it in a sealed room.”
I also consider a carbon monoxide detector part of the setup.
β First Alert CO615 Carbon Monoxide Alarm with Battery Backup
I use this model at home because it has a digital CO display along with battery backup.
π Carbon Monoxide Poisoning Symptoms and Prevention
Buddy Heater Ventilation Requirements
Here are the important numbers for the two most common Buddy Heater models.
| Buddy Heater | Maximum Output | Low Opening | High Opening |
|---|---|---|---|
| Portable Buddy MH9BX | 9,000 BTU | 9 sq. in. minimum | 9 sq. in. minimum |
| Big Buddy MH18B | 18,000 BTU | 18 sq. in. minimum | 18 sq. in. minimum |
These areas are not combined. A Big Buddy needs an 18-square-inch low opening and an 18-square-inch high opening. A Portable Buddy needs 9 square inches at each location.
For the Portable Buddy, Mr. Heater gives a 3-inch by 3-inch opening as the example. That equals 9 square inches.
For the Big Buddy, the example is approximately 4.25 inches by 4.25 inches, which works out to just over 18 square inches.
The current manuals specify ventilation at the ceiling and at floor level. That’s an important detail because a single small window crack isn’t necessarily the same thing as providing both a high and low air path.
In a typical room, two separate windows are a practical way to provide openings at different heights. With double-hung sash windows, for example, you could open the bottom sash of one window and the upper sash of another window elsewhere in the room. This separates the low and high air paths instead of relying on one opening.
Keep in mind that Mr. Heater’s instructions actually specify ventilation at floor level and ceiling level. Ordinary windows may not be located that low or high, so the sash-window example is a practical approximation rather than a substitute for following the exact ventilation instructions for your particular installation.
How Far Should You Crack a Window for a Buddy Heater?
This is probably the more practical question.
Ventilation requirements are given in square inches, not “open the window one inch.” The actual opening depends on the width of the window.
Area is simply:
Window width Γ opening height = square inches of opening
For example, consider a 30-inch-wide window.
For 9 square inches:
30 Γ 0.30 inches = 9 square inches
For 18 square inches:
30 Γ 0.60 inches = 18 square inches
Here’s what that looks like with several common window widths:
| Window Width | 9 Sq. In. Opening | 18 Sq. In. Opening |
|---|---|---|
| 24 inches | 3/8 inch | 3/4 inch |
| 30 inches | about 1/3 inch | about 5/8 inch |
| 36 inches | 1/4 inch | 1/2 inch |
Remember, this amount applies to each opening separately. For example, with a Big Buddy and two 30-inch-wide windows, you would need roughly a 5/8-inch opening at the low window and another roughly 5/8-inch opening at the high window.
This is only the geometry. I wouldn’t use this table as an excuse to squeeze the ventilation down to the absolute minimum.
Screens, curtains, snow, window design, and restricted airflow can all reduce the effective opening. More important, the current Buddy manuals call for ventilation at both high and low levels.
Using two openings at different heights makes more sense than trying to calculate the smallest possible crack in one window.
Why Does a Buddy Heater Need Ventilation If It Is Indoor Safe?
A Buddy Heater burns propane.
That combustion requires oxygen from the room. It also produces combustion gases and water vapor that need somewhere to go.
Mr. Heater describes the Portable Buddy as an unvented gas-fired heater that uses oxygen from the area where it operates. Its instructions specifically require adequate combustion and ventilation air.
The heater does have an Oxygen Depletion Sensor, or ODS, which can shut down the heater if there isn’t enough fresh air. Both the Portable Buddy and Big Buddy also have tip-over safety shutoffs.
Those safety systems are good to have. They do not eliminate the ventilation requirement.
And an ODS should not be confused with a carbon monoxide detector.
The ODS is part of the heater’s safety system. A separate CO alarm is an independent warning device watching the air you’re actually breathing.
I want both.
What Kind of Heat Does a Buddy Heater Produce?
The Buddy Heater is a radiant propane heater. Its burner heats a ceramic tile until it becomes very hot, and that surface sends infrared heat outward toward people and objects in front of it. It does not use the same forced-air burner arrangement found in many large propane construction heaters.
The ceramic radiant burner alone is not what makes a Buddy Heater suitable for indoor use. The Buddy series is specifically designed and certified for indoor use where local rules allow it, and it includes an Oxygen Depletion Sensor (ODS) and an accidental tip-over shutoff. You still need the ventilation specified in the owner’s manual.
Does a Carbon Monoxide Detector Replace Ventilation?
No.
A CO detector tells you when carbon monoxide has reached the alarm’s detection threshold. It does nothing to supply fresh air to the heater.
Likewise, opening a window doesn’t replace the CO detector.
Think of them as separate parts of the setup. The heater gets the combustion air called for by its instructions, while the CO detector provides another layer of warning if something goes wrong.
If a CO alarm ever activates while you’re using a heater, don’t assume that opening the window a little farther solves the problem. Get outside into fresh air and determine why the alarm activated.
π Carbon Monoxide Poisoning Symptoms and Prevention
What If the Buddy Heater Keeps Shutting Off?
A Buddy Heater that repeatedly shuts itself off may be telling you something.
The Big Buddy manual specifically says that if the heater shuts off, fresh air should be provided before relighting it. If it continues shutting off, the heater should be serviced. The troubleshooting section also lists inadequate fresh air as one possible reason for repeated shutdowns.
Don’t defeat or modify the ODS to keep a heater running.
There are other possible causes for shutdowns, including a dirty pilot, a bumped tip-over switch, high altitude, or a fuel-flow problem. But ventilation is one of the first things to check.
Mr. Heater also notes that operation above about 7,000 feet can cause nuisance shutdowns because of the lower oxygen level at altitude.
What About Using a 20-lb Propane Tank?
Using a larger propane tank changes the fuel supply, but it does not make the heater’s ventilation requirement go away.
A 20-pound tank is especially useful during an extended outage because the runtime can be measured in days rather than hours.
π How Long Will a Buddy Heater Run on 1 lb & 20 lb Propane Tanks? (Run-Time Chart & Tips)
For my Buddy Heater setup, I would use the proper Mr. Heater hose rather than a random generic propane hose.
The F273704 is particularly useful because Mr. Heater says this particular hose does not require the separate Buddy fuel filter. It is made from a different hose material that does not release the oily contaminants associated with some other high-pressure propane hoses.
β Mr. Heater F273704 10-Foot Buddy Series Hose (Amazon)
If you’re using a bulk propane cylinder with a heater indoors, the cylinder itself should remain outside and the approved hose routed to the heater. Mr. Heater product guidance also distinguishes between the indoor-safe heater and the larger propane cylinder used to supply it.
Can You Run a Buddy Heater in a Closed Room?
No. Don’t seal the room.
The whole idea behind an indoor-rated Buddy Heater is that it can operate in an appropriate enclosure with the required fresh-air ventilation.
The Portable Buddy manual specifically says not to use the heater inside a recreational or commercial enclosure if there is no window or roof vent. It also warns against using the heater in an unventilated area.
A newer, tightly built house makes this even more worth thinking about. Older homes often leak quite a bit of outside air around windows, doors, and other openings. Modern construction can be much tighter.
I would not count on accidental air leaks through a house as my ventilation plan.
Open the required vents intentionally.
Can You Sleep With a Buddy Heater Running?
I wouldn’t.
More important, the Mr. Heater operating instructions specifically warn: never operate the heater while sleeping.
For emergency heat, a better approach is to warm the room while you’re awake, shut the heater down before sleeping, and use good blankets or sleeping bags to hold your body heat.
Then run the heater again when you’re awake.
This also saves quite a bit of propane during a long outage.
If fuel supply is part of your planning, my Buddy Heater runtime article includes approximate hours for both 1-pound cylinders and 20-pound tanks at the different heat settings.
π How Long Will a Buddy Heater Run on 1 lb & 20 lb Propane Tanks? (Run-Time Chart & Tips)
Buddy Heater Indoor Ventilation: My Practical Take
The useful numbers are easy to remember:
Portable Buddy MH9BX: 9 square inches at the high opening + 9 square inches at the low opening.
Big Buddy MH18B: 18 square inches at the high opening + 18 square inches at the low opening.
Those are minimum ventilation requirements from the manufacturer, not targets to beat by making the opening as small as mathematically possible.
Give the heater fresh air. Keep the openings clear. Use a CO detector. Don’t run the heater while sleeping.